24 10/100TX PoE at + 4 Dual Speed SFP L2+ Industrial Managed Switch

  • High-density 10/100TX L2+ managed PoE at/af switch
  • Enhanced G.8032 ring protection < 20ms for single ring. Supports auto mode, enhanced mode, train mode and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 8/16* MSTI /RSTP
  • Supports PoE management
  • Support LACP link aggregation, IGMP v3/router port, DHCP server & DHCP Option82 for Port/Vlan based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH/SSL, HTTPS, INGRESS/EGRESS ACL L2/L3, IPv6, SMS
  • Miss-wiring avoidance & Repowered auto ring restore
  • User friendly UI, including auto topology drawing and DDM threshold monitoring with dB values***, Complete CLI supported
  • USB slot for edited restoration and auto backup



Datasheet   Hardware Manual   Web UI User's Manual
For latest firmware, please send request to support@lantechcom.tw

OVERVIEW

Lantech IPES-3424DSFP-2P is a high performance L2 + PoE managed industrial switch which provides L2 wire speed and advanced security function for network aggregation and backbone deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms including dynamic coupling ring, and enhanced mode for easy configuration, comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ* (double tag VLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.


Compliant with IEEE802.3at/af standard, the Lantech IPES-3424DSFP-2P is able to feed each PoE port up to 30Watts@54VDC providing the connected PD devices at Gigabit speed. It also supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD is still alive then sending power; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Per port PoE status explicits voltage, current, watt and poe temperature information.


Lantech IPES-3424DSFP-2P features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over Vlan for redundant links with 8/16* MSTI.


The IPES-3424DSFP-2P also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPES-3424DSFP-2P is able to alert with the LED indicator and send out an email, traps or a SMS text. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed when power back. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.


DHCP option 82 and relay agent function (Port/Vlan based DHCP distribution) can offer the same IP address on port base or vlan base where there is need to replace the new device connecting to Lantech switches to avoid any network disruption. The built-in DHCP Option 82 server offers the convenience of policy setting on the switch. Mac based DHCP server function assigns an IP address according to its MAC address to include dumb switches in DHCP network.


The user friendly UI, innovative auto topology drawing and topology demo makes IPES-3424DSFP-2P much easier to get hands-on. The IPES-3424DSFP-2P supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI support allows professional setting.

Lantech IPES-3424DSFP-2P can export the configuration in editable configuration file making the mass deployment easier.


Lantech IPES-3424DSFP-2P configuration can be exported and editable which makes the mass deployment easier. Also, it designs with a factory reset button where user can reset all settings to factory default. The built-in watch dog design can reboot switch automatically when CPU is found dead. IPES-3424DSFP-2P supports USB dongle where can automatically back up the configuration or editable restoration for easy maintenance swapping a broken switch.


QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.


The IPES-3424DSFP-2P DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IPES-3424DSFP-2P will immediately send an email, SMS text to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors into the auto alarm system and transfer the alarm information to IP network with email, text and SNMP.


Lantech IPES-3424DSFP-2P supports PoE power inputs from DC45~56V with dual system power. It features high reliability and robustness withstanding extensive EMI/RFI phenomenon, lighting surge, inductive load switching, high ESD, high fault current environment usually found in Substation, Steel automation, Mining and Process control etc. Supporting the latest EEE (Efficient Energy Ethernet) standard, IPES-3424DSFP-2P can run under widely operational temperature (-40°C~75°C) in the harsh environment.


*Future Release
**Optional
***Optional DDM SFP required

FEATURES

  • System Interface/Performance
    • 24x10/100TX PoE at/af+ 4 100M/1000M SFP L2+
    • 16K MAC Address Table
    • Dual Power Supply Design for DC(9.5V~60VDC), AC(85V~265VAC) or 100V~370VDC
    • PoE power input with budget up to 720W
    • -40to 75C operation temperature(-E model)
  • PoE management including PoE detection and scheduling for PD (power devices); per Port PoE status includes voltage, current, watt and PoE temperature
  • DDM to support SFP diagnostic function***
    • Automatically convert the raw data into dB values for TX power/RX power, making it easier to measure the fiber distance
  • VLAN
    • 4K 802.1Q Vlan, Port Based VLAN,GVRP**,QinQ*,MVRP*
  • Port Trunk with LACP 127 trunks with automatic link failover
  • QoS (Quality of Service)
  • Port Trunk with LACP 127 trunks with automatic link failover
  • Security
    • SSL/SSH/INGRESS/EGRESS ACL L2/L3
    • Port Security: MAC address entries/Filter/MAC-Port binding
    • IP Security: IP address security management to prevent unauthorized intruder.
    • Management access control with priority
    • Login Security: IEEE802.1X/RADIUS
    • HTTPS for secure access to the web interface
  • Miss-wiring avoidance
    • LED indicator
    • Email, traps, or SMS notification
  • Repowered auto ring restore (node failure protection)
    • Ensure the switches in a ring to survive after power breakout is back
    • The status can be shown in NMS when each switch is back
  • IGMP v1,v2,v3 for video surveillance application; GMRP*
  • IGMP Query mode and support dynamic IGMP router port for reversed multicast video flow and assign another query in a ring
  • Enhanced G.8032 Ring protection in 20ms for single ring
    • Support various ring/chain topologies, including dynamic coupling ring
    • Enhanced G.8032 ring configuration with ease
    • Auto ring configuration(auto mode) for single ring
    • Ring covers multicast on different ports
  • Auto topology drawing in web UI with detail node info
  • Auto configurator for auto ITU ring setup
  • 256 groups MSTP over VLAN
  • Supports IEEE802.1ab LLDP, Cisco CDP
  • DHCP server / client / DHCP Option 82 relay / DHCP Option 82 server for Port/Vlan based DHCP distribution
  • Mac based DHCP server to assign IP address that includes dumb switches in DHCP network
  • Bandwidth Control
    • Ingress Packet Filter and Egress Rate Limit
    • Broadcast/Multicast Packet Filter Control
  • System Event Log, Email alert, SMS(mobile text) and SNMP Trap for alarm support; 32 RMON
  • TFTP/HTTP Firmware upgrade; Redundant firmware to avoid crashing in case of upgrade failure
  • Reset / Factory default button to restore factory setting
  • Watch dog design to reboot switch under certain circumstances
  • Provides EFT protection ±4000 VDC for power line
  • Supports ±8000 VDC Ethernet ESD protection
  • 2 DI/DO and 1 relay contact alarm
  • Support USB dongle for auto backup/edited restoration configuration
*Future Release
**Optional
***Optional DDM SFP required

SPECIFICATIONS

Hardware Specifications

IEEE Standards

IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Ethernet
IEEE802.3z Gigabit fiber
IEEE 802.3x Flow Control Capability
ANSI/IEEE 802.3 Auto-negotiation
IEEE 802.1Q VLAN
IEEE 802.1p Class of Service
IEEE 802.1X Access Control
IEEE 802.1D Spanning Tree
IEEE 802.1w Rapid Spanning Tree
IEEE 802.1s Multiple Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
IEEE 802.1x User Authentication (Radius)
IEEE 802.3t/af Power Over Ethernet

Switch Architecture

Back-plane (Switching Fabric): 12.8Gbps

Transfer Rate

14,880pps for Ethernet port
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Ethernet / Gigabit Fiber port

CPU

Marvell 800Mhz

RAM

256M Byte

Flash

128M Byte

Mac Address

16K MAC address table

Jumbo frame

10KB on all ports

PoE pin assignment

RJ-45 port # 1~# 24 support PoE at/af End-point,
Alternative A mode. Per port provides up to 30W@54V capability.
Positive (VCC+): RJ-45 pin 1,2.
Negative (VCC-): RJ-45 pin 3,6.

PoE input voltage & Power feed voltage

Input V

Active Mode A /Output V

45~56V(af)

48V@15W

54~56V(at)

54V@30W

Connectors

24 10/100TX RJ-45 with auto MDI/MDI-X function
4 100M / 1000M Mini-GBIC : SFP sockets
RS-232 console: Female DB-9
USB for backup and restore

DDM

Conform to SFF-8472 to show diagnostic SFP with temperature, current, voltage, input and output power

Protocol

CSMA/CD

LED

Per unit: Power 1 (Green), Power 2 (Green), Fault (Red) ,R.M (Green)                                       
Link/Activity (Green), Full duplex/collision(Yellow)), MINI GBIC (Link/Activity )(Green) 

Power Supply

Two power sockets for switch system,
9.5~60VDC input
IEC320 85~265VAC input (-AC model)
AC/DC 85~265VAC/100V~370VDC input (-HV model)
48VDC for PoE

Power Consumption

Full load: 30W/ Unload: 13W

PoE Power Budget

720W

Relay Alarm

Provides one relay output for port breakdown, power fail and alarm.
Alarm Relay current carry ability: 1A @ DC24V

DI/DO

2 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
2 Digital Output(DO): Open collector to 40 VDC, 200mA

RTC

RTC(Real Time Clock) to keep track of time always

Factory reset button & watch dog design

Factory reset button to restore back to factory default settings.  Watch dog design can reboot switch automatically when CPU is found dead

Case Dimension

19” Metal case,IP-30; 440mm(W)x325mm(D)x44mm(H)

Operating Humidity

5%~95% (Non-condensing)

Operating Temperature

Standard: -40°C ~60°C
Extended temperature : -40°C ~75°C

Storage Temperature

-40°C ~85°C

EMI

FCC Class A, CE EN61000-4-2 (ESD),
CE EN61000-4-3 (RS), CE EN-61000-4-4 (EFT),
CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS),
CE EN61000-4-8
CE EN55032 Class A, CE EN55024

Stability Testing

IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration), KEMA 61850-3,
IEEE1613, Zero packet loss(240~480V)
IEC60870-2-2, IEC60068-2-30

Warranty

5 years

Software Specifications

Management

SNMP v1 v2c, v3/ Web/Telnet/CLI Management

SNMP MIB

RFC 1215 Traps MIB,
RFC 1213 MIBII
RFC 1158 MIBII
RFC 1157 SNMP MIB,
RFC 1493 Bridge MIB,
RFC 1573 IF MIB
RFC 2674 VLAN MIB,
Partial RFC 1757 RMON,
RFC 2674 Q-Bridge MIB; Bridge MIB,
LLDP MIB*
RSTP MIB*
Private MIB

VLAN

Port based VLAN, up to 28 groups
IEEE802.1Q Tag VLAN
Static VLAN groups up to 256, Dynamic VLAN group up to 2048, VLAN ID from 1 to 4096.
GVRP up to 256 groups**
Multiple VLAN Registration*

Port Trunk with LACP

LACP Port Trunk: 8 Trunk groups/Maximum 24 trunk members with failover

LLDP

Support LLDP to allow switch to advise its identification and capability on the LAN

CDP

Cisco Discovery protocol for topology mapping

ITU G.8032

Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (basic mode)
Support various ring/chain topologies
Includes dynamic coupling ring
Enhanced G.8032 ring configuration with ease
Ring covers multicast on different ports

User friendly UI

  1. Auto topology drawing with detail node info
  2. DDM threshold monitoring with dB values***
  3. Complete CLI for professional setting

Spanning Tree

Support IEEE802.1d Spanning Tree,IEEE802.1w Rapid Spanning Tree, IEEE 802.1s MSTP

Quality of Service

The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Differentiated Services Code Points - DSCP

Class of Service

Support IEEE802.1p class of service, per port provides 8 priority queues

QoS by VLAN

Tagged QoS by VLAN for all devices in the network

Port Security

Support 50 entries of MAC address for static MAC and another 50 for MAC filter

Port Mirror

Support 3 mirroring types: “RX, TX and Both packet”

Multicast Filtering & IGMP

Dynamic:
Support IGMP snooping v1, v2,v3
Support 256 multicast groups
Support IGMP query
Support Dynamic IGMP router port for multicast reversed video flow GMRP*

Static MAC-Port bridge

Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application

Bandwidth Control

Support ingress packet filter and egress packet limit.
The egress rate control supports all of packet type,  the limit rates are 0~100Mbps.
Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet. The packet filter rate can be set from 0 to 100Mbps
The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit.

Network Security

Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.
802.1X access control for port based and MAC based authentication/MAC-Port binding
Management access control with priority
Ingress/Egress ACL L2/L3
SSL/ SSH for Management
HTTPS for secure access to the web interface
TACACS+* for Authentication

Protection

  1. Miss-wiring avoidance
  2. Repowered auto ring restore (node failure protection)
  3. Loop protection

PoE Management

  1. PoE Detection to check if PD hangs then restart the PD
  2. PoE Scheduling to On/OFF PD upon routine time table
  3. Per port PoE status including voltage, current, watt and PoE temperature

Flow Control

Support Flow Control for Full-duplex and Back Pressure for Half-duplex

System Log

Support System log record and remote system log server

SMTP, SMS

Supports SMTP Server and 8 e-mail accounts for receiving event alert; can send SMS text alert via mobile; Can send alert via mobile SMS text

SNMP Trap

Up to 10 trap stations; trap types including:

  1. Device cold start
  2. Authorization failure
  3. Port link up/link down
  4. DI/DO open/close
  5. Typology change(ITU ring)
  6. PoE ping failure
  7. Power failure

DHCP

Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based&VLAN based DHCP distribution (DHCP relay agent)

Mac based DHCP Server

Assign IP address by Mac that can include dumb switch in DHCP network

DNS

Provide DNS client feature and support Primary and Secondary DNS server.

SNTP

Support SNTP to synchronize system clock in Internet

Firmware Update

Support TFTP /HTTPS firmware update ; InstaConfig mass firmware upgrade**

Configuration backup and restore

Support text backup and restore; USB dongle for firmware auto-backup and edited restoration

*Future Release
**Optional
***Optional DDM SFP required

DIMENSION

ORDER INFORMATION

P/N Model name Description
8380-602 IPES-3424DSFP-2P 24 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch

Built-in 1x isolated DC 12~56VDC power supply + 1x additional power socket + 1x 48VDC PoE power input; -20°C to 60°C
8380-603 IPES-3424DSFP-2P-E 24 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch

Built-in 1x isolated DC 12~56VDC power supply + 1x additional power socket + 1x 48VDC PoE power input; -40°C to 75°C
8380-604 IPES-3424DSFP-2P-AC 24 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch

Built-in 1x isolated AC85~265VAC IEC320 power supply + 1x additional power socket + 1x 48VDC PoE power input; -20°C to 60°C
8380-605 IPES-3424DSFP-2P-AC-E 24 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch

Built-in 1x isolated AC85~265VAC IEC320 power supply + 1x additional power socket + 1x 48VDC PoE power input; -40°C to 75°C
8380-606 IPES-3424DSFP-2P-HV 24 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch

Built-in 1x isolated AC/DC 85~265VAC/100V~370VDC power supply + 1x additional power socket + 1x 48VDC PoE power input; -20°C to 60°C
8380-607 IPES-3424DSFP-2P-HV-E 24 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch

Built-in 1x isolated AC/DC 85~265VAC/100V~370VDC power supply + 1x additional power socket + 1x 48VDC PoE power input; -40°C to 75°C


OPTIONAL ACCESSORIES - DIN Rail Power

Model name Description
NDR-480 Series 480W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
NDR-240 Series 240W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
NDR-120 Series 120W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)
NDR-75 Series 75W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)


OPTIONAL ACCESSORIES - Mini GBIC (SFP)

Model name Description Model name Description
8330-162X MINI GBIC 1000SX (LC/0.5KM) Transceiver 8330-187 LTSFP-1000BX-20KM Transceiver (WDM 1550)
8330-163X MINI GBIC 1000SX2 (LC/2KM) Transceiver 8330-180 LTSFP-1000BX-40KM Transceiver (WDM 1310)
8330-165X MINI GBIC 1000LX (LC/10KM) Transceiver 8330-182 LTSFP-1000BX-40KM Transceiver (WDM 1550)
8340-0591 MINI GBIC 1000LHX (LC/40KM) Transceiver 8330-181 LTSFP-1000BX-60KM Transceiver (WDM 1310)
8330-166 MINI GBIC 1000XD (LC/50KM) Transceiver 8330-183 LTSFP-1000BX-60KM Transceiver (WDM 1550)
8330-169 MINI GBIC 1000XD (LC/60KM) Transceiver 8330-184 LTSFP-1000BX-80KM Transceiver (WDM 1490)
8330-167 MINI GBIC 1000ZX (LC/80KM) Transceiver 8330-185 LTSFP-1000BX-80KM Transceiver (WDM 1550)
8330-170 MINI GBIC 1000EZX (120KM) Transceiver 8330-071 125Mbps BiDi SFP 2KM (WDM 1310) Transceiver
8330-168 MINI GBIC 10/100/1000T (100m) Transceiver 8330-072 125Mbps BiDi SFP 2KM (WDM 1550) Transceiver
8330-060 100Base FX 2KM, Multi-mode, LC Transceiver 8330-069 125Mbps BiDi SFP 20KM (WDM 1310) Transceiver
8330-065 100Base FX 5KM, Multi-mode, LC Transceiver 8330-068 125Mbps BiDi SFP 20KM (WDM 1550) Transceiver
8330-061 100Base LX 30KM, Single-mode, LC Transceiver 8330-080 125Mbps BiDi SFP 40KM (WDM 1310) Transceiver
8330-197 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1310) 8330-082 125Mbps BiDi SFP 40KM (WDM 1550) Transceiver
8330-198 1.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1550) 8330-081 125Mbps BiDi SFP 60KM (WDM 1310) Transceiver
8330-195 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1310) 8330-083 125Mbps BiDi SFP 60KM (WDM 1550) Transceiver
8330-196 1.25Gbps BiDi SFP 2KM Transceiver (WDM 1550) 8330-084 125Mbps BiDi SFP 80KM (WDM 1310) Transceiver
8330-188 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1310) 8330-085 125Mbps BiDi SFP 80KM (WDM 1550) Transceiver
8330-189 1.25Gbps BiDi SFP 10KM Transceiver (WDM 1550) 8330-191 Dual Speed SFP 100M/1000M-LX 10KM Transceiver
8330-186 1.25Gbps BiDi SFP 20KM Transceiver (WDM 1310) All SFP P/N# ended with D are with DDM function