8 10/100/1000T + 4 1G/2.5G SFP OS3 (w/16 PoE af/at) Industrial Managed Ethernet Rackmount Switch; Dual DCI power inputs


IEC 61850-3 CE UKCA FCC WEEE RoHS2 PoE 802.3at/af 30W Environmental Monitoring USB L3L - Layer3 Lite L3 - Layer3


Hardware Datasheet   Software Datasheet   Hardware Manual  
For latest firmware and web UI user manual, please contact us.

OVERVIEW

Lantech I(P)GS-L5408MGSFPR-DCI is a high performance OS3 Industrial Ethernet switch with 8 10/100/1000T + 4 1G/2.5G SFP which provides advanced security function for network aggregation deployment. PoE model has 8 PoE 802.3af/at ports.


Up to 8 PoE at/af ports w/advanced PoE management; Ethernet power input galvanic isolation
Compliant with 802.3af/at standard, the PoE model is able to feed each PoE port up to 30 Watt at each PoE port for various IP PD devices. It supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE ports can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.


Galvanic isolation between power input and Ethernet power system, also the PoE galvanic isolation provides insulation between the power input to PoE Ethernet ports, preventing cabling and grounding incidents from damaging the Ethernet switch. The efficiency of the galvanically decoupled voltage converters can reach above 90%. (DCI model)


Lantech OS3 Platform with complete L2 management and upgradable optional L3 & communication protocols
The switch runs Lantech OS3 platform which is powerful with complete Layer 2 management features and optional upgradable for future expansion, such as Layer 3 Lite, Layer 3, etc. To learn more about the Lantech OS3 Platform, please refer to Lantech OS3/OS4 platform


Enhanced cybersecurity features with IEC 62443-4-1 certification
Lantech OS3 platform is designed with high standard of cybersecurity to prevent the threats from network attack such as DDoS attacks. To ensure the safety and reliability of communication networks, Lantech develops our products under strict international security standard and is certified with IEC 62443-4-1 network security standard. To learn more about Lantech cybersecurity software solution, please refer to Lantech OS3/OS4 platform


Miss-wiring avoidance, node failure protection, Loop protection
The switch also embedded several features for strong and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, the switch being able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.


User friendly GUI, Auto topology drawing, Enhanced Environmental Monitoring
The user-friendly UI, innovative auto topology drawing and topology demo makes the switch much easier to get hands-on. The complete CLI enables professional engineer to configure setting by command line. It supports enhanced environmental monitoring for actual input voltage, current, ambient temperature and total power load.


Editable configuration file; USB port for import/export configuration; optional out-of-band management via 1000T Ethernet port
The configuration file of the switch can be imported and edited with word processor for the following switches to configure with ease. The USB port can import/export the configuration from/to USB dongle and also to upgrade firmware from USB dongle. TFTP/HTTP firmware upgrade is supported.


The console port can act as OOB** management for remote service and management.


Dual DCI power supplies
The switch is designed with dual isolated power supplies at 50~56VDC (For PoE model) and 12~48VDC (For Non PoE model) with terminal block.


Industrial hardened design with high EFT and ESD protection
The switch features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control.


It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory applications. The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.


*Future release
**Optional

SPECIFICATIONS

Hardware Specifications

Standards

IEEE802.3 10Base-T Ethernet
IEEE802.3u 100Base-TX
IEEE802.3ab 1000Base-T
IEEE802.3x Flow Control and Back Pressure
IEEE802.3ad Port trunk with LACP
IEEE802.1d Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1s Multiple Spanning Tree
IEEE802.3ad Link Aggregation Control Protocol (LACP)
IEEE802.1AB Link Layer Discovery Protocol (LLDP)
IEEE802.1X User Authentication (Radius)
IEEE802.1p Class of Service
IEEE802.1Q VLAN Tag
IEEE802.3at/af Power over Ethernet (PoE model)

Switch Architecture

Back-plane (Switching Fabric): 36Gbps

Mac Address

16K MAC address table

Jumbo frame

10KB

Connectors

10/100/1000T: 8 x ports RJ-45 with Auto MDI/MDI-X function
Mini-GBIC: 4 x 1G/2.5G SFP socket with DDMI
RS-232 connector: RJ-45 type for CLI; optional 100Mbps Ethernet for management out-of-band feature
USB x 1
Power connector: 6-pin terminal block

Network Cable

100Base-TX: 2-pair STP Cat. 5/ 5E/ 6 cable; EIA/TIA-568 100-ohm (100m)
1000Base-T: 4-pair STP Cat5E/6 cable
1G/2.5G Copper: 4-pair STP Cat6a/7 cable

Optical Cable

1Gbps:
Multi-mode: 0 to 550 m, 850 nm (50/125 μm); 0 to 2 km, 1310 nm (50/125 μm)
Single mode: 0 to 10 km/ 30 km/ 40 km, 1310 nm (9/125 μm); 0 to 50 km/ 60 km/ 80km/ 120 km, 1550 nm (9/125 μm)
2.5Gbps
Multi-mode: 0 to 300 m, 850 nm (50/125 μm);
Single mode: 0 to 2 km/ 15 km/ 40 km, 1310 nm (9/125 μm); 0 to 40 km/ 80 km/ 100km, 1550 nm (9/125 μm)
WDM 1Gbps:
Single-mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1310 nm (9/125 μm); 0 to 80 km, 1490 nm (9/125 μm); 0 to 10 km/ 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125 μm)
WDM 2.5Gbps
Single-mode: 0 to 5 km/ 20 km/ 40 km/ 60 km, 1310 /1550nm (9/125 μm); 0 to 80 km, 1490/1550 nm (9/125 μm)

LED

Per unit: Power 1 (Green), Power 2 (Green), FAULT (Red); RM(Green)
10/100/1000T Ethernet port: Link/Activity (Green)
1G/2.5G fiber: Link/Act (Orange)

Operating Humidity

5% ~ 95% (non-condensing)

Operating Temperature

-40°C~70°C / -40°F~167°F

Storage Temperature

-40°C~85°C / -40°F~185°F

Power Supply

Dual DCI power inputs,
50~56VDC with PoE and Ethernet galvanic isolation (for PoE model)
12~48VDC with Ethernet galvanic isolation (For Non PoE model)

PoE Budget (PoE model)

120W@54V (50-56VDC input is recommended for 802.3at 30W applications)
Higher PoE budget can be applied upon request. **

PoE pin assignment (PoE model)

M12 port #1~#8; support IEEE 802.3at/af End-point, Alternative A mode

Power Consumption

Max. 30.5W (For PoE model), 28W (For Non PoE model)

Case Dimension

Metal case. IP-30,
440mm(W)x255mm(D)x44mm(H)

Weight

3.2kg

Installation

Rack Mount Design

EMI & EMS

EN 50121-4:2016/A1:2019
EN 50121-5:2017/A1:2019
EN 55035:2017/A11:2020
EN 55032:2015/A11:2020
FCC Part 15, Subpart B
ICES-003 Issue 7-2020
IEC 61000-4-9:2016
IEC 61000-4-10:2016
IEC 61000-6-5:2015
IEC 61000-6-2:2016
IEC 61000-6-4:2018
EN IEC 61000-6-2:2019
EN 61000-6-4:2019
BS EN 55035:2017+A11:2020
BS EN 55032:2015+A1:2020

Verifications

IEC 61850-3:2013
IEEE 1613:2009
EN 50155:2021

MTBF

645,121 hrs (standards: IEC 62380)

Warranty

5 years

Software Specifications

Lantech OS3 Platform

Learn more about Lantech OS3 Platform

*Future release
**Optional

DIMENSION

ORDERING INFORMATION

P/N Model name Description
8350-85746 IPGS-L5408MGSFPR-DCI 8 10/100/1000T + 4 1G/2.5G SFP w/8 PoE 802.3af/at OS3 Managed Ethernet Switch; dual 50~56VDC power inputs with PoE galvanic isolation; -40°C to 70°C; IP30 Rackmount design
8350-85741 IGS-L5408MGSFPR-DCI 8 10/100/1000T + 4 1G/2.5G SFP OS3 Managed Ethernet Switch; dual 12~48VDC power inputs with galvanic isolation; -40°C to 70°C; IP30 Rackmount design
8350-85746OOB IPGS-L5408MGSFPR-DCI 8 10/100/1000T + 4 1G/2.5G SFP w/8 PoE 802.3af/at OS3 Managed Ethernet Switch; dual 50~56VDC power inputs with PoE galvanic isolation; -40°C to 70°C; IP30 Rackmount design w/Out of band management feature
8350-85741OOB IGS-L5408MGSFPR-DCI 8 10/100/1000T + 4 1G/2.5G SFP OS3 Managed Ethernet Switch; dual 12~48VDC power inputs with galvanic isolation; -40°C to 70°C; IP30 Rackmount design w/Out of band management feature


OPTIONAL ACCESSORIES - Software package

Please refer to Lantech OS3/OS4 platform


OPTIONAL ACCESSORIES - Mini GBIC (SFP)

Model name Description Model name Description
8330-162-V1 MINI GBIC 1000SX (LC/0.5km) Transceiver 8330-186-V1 LTSFP-1000BX-20KM Transceiver (WDM 1310)
8330-163-V1 MINI GBIC 1000SX2 (LC/2km) Transceiver 8330-187-V1 LTSFP-1000BX-20KM Transceiver (WDM 1550)
8330-165-V1 MINI GBIC 1000LX (LC/10km) Transceiver 8330-180-V1 LTSFP-1000BX-40KM Transceiver (WDM 1310)
8340-0591-V1 MINI GBIC 1000LHX (LC/40km) Transceiver 8330-182-V1 LTSFP-1000BX-40KM Transceiver (WDM 1550)
8330-166-V1 MINI GBIC 1000XD (LC/50km) Transceiver 8330-181-V1 LTSFP-1000BX-60KM Transceiver (WDM 1310)
8330-169-V1 MINI GBIC 1000XD (LC/60km) Transceiver 8330-183-V1 LTSFP-1000BX-60KM Transceiver (WDM 1550)
8330-167-V1 MINI GBIC 1000ZX (LC/80km) Transceiver 8330-184-V1 LTSFP-1000BX-80KM Transceiver (WDM 1490)
8330-170-V1 MINI GBIC 1000EZX (120km) Transceiver 8330-185-V1 LTSFP-1000BX-80KM Transceiver (WDM 1550)
8330-168-V1 MINI GBIC 1000T (100m) Transceiver 8330-262D-V1 MINI GBIC 2.5G 850nm VCSEL (LC/0.3km) Transceiver
8330-188-V1 LTSFP-1000BX-10KM Transceiver (WDM 1310) 8330-263D-V1 MINI GBIC 2.5G 1310nm FP (LC/2km) Transceiver
8330-189-V1 LTSFP-1000BX-10KM Transceiver (WDM 1550) 8330-265D-V1 MINI GBIC 2.5G 1310nm DFB (LC/15km) Transceiver
All SFP P/N# ended with D are with DDM function