24 10/100/1000T + 2 10G Copper + 2 10G Fiber Q-ODC OM3 (w/8/16 PoE at/af) EN50155 OS3 Managed Ethernet Switch; WVI input


CE UKCA FCC WEEE RoHS2 EN45545-2  Fire & Smoke EN50155 10GbE speed PoE 802.3at/af 30W Wide power input range with isolation Environmental Monitoring IEC 61375-2-5 ETBN L3L - Layer3 Lite L3 - Layer3


Hardware Datasheet   Software Datasheet   Hardware Manual  
For latest firmware and web UI user manual, please send request to support@lantechcom.tw

OVERVIEW

Lantech T(P)GS-L6424XFTR is a high performance OS3 full Gigabit Ethernet switch with 24 10/100/1000T + 2 1G/2.5G/5G/10G copper + 2 1G/10G SR/LR Fiber Q-ODC OM3. PoE model has 8/16 PoE 802.3af/at ports which provides advanced security function for network aggregation deployment.


Up to 8/16 PoE at/af ports w/advanced PoE management and PoE galvanic isolation
Compliant with 802.3af/at standard, the PoE model is able to feed each PoE port up to 30 Watt at each PoE port for various IP PD devices. It supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE ports can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.


PoE galvanic isolation up to 1.5KVDC to provide power input to PoE Ethernet ports insulation prevents cabling and grounding incidents from damaging the Ethernet switch itself.


Lantech OS3 Platform with complete L2 management and upgradable optional L3 & communication protocols
The switch runs Lantech OS3 platform which is powerful with complete Layer 2 management features and optional upgradable for future expansion, such as Layer 3 Lite, Layer 3, IEC61375-2-5 (ETBN), etc. To learn more about the Lantech OS3 Platform, please refer to Lantech OS3/OS4 platform


Enhanced cybersecurity features with IEC 62443-4-1 certification
Lantech OS3 platform is designed with high standard of cybersecurity to prevent the threats from network attack such as DDoS attacks. To ensure the safety and reliability of communication networks, Lantech develops our products under strict international security standard and is certified with IEC 62443-4-1 network security standard. To learn more about Lantech cybersecurity software solution, please refer to Lantech OS3/OS4 platform


Miss-wiring avoidance, node failure protection, Loop protection
The switch also embedded several features for strong and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, the switch being able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.


User friendly GUI, Auto topology drawing, Enhanced Environmental Monitoring
The user-friendly UI, innovative auto topology drawing and topology demo makes the switch much easier to get hands-on. The complete CLI enables professional engineer to configure setting by command line. It supports enhanced environmental monitoring for actual input voltage, current, ambient temperature and total power load.


Built-in IEC 61375-3-4 ECN (Ethernet Consist Network) to work with IEC61375-2-5 TBN
Lantech OS3 Ethernet switches comply with IEC 61375-3-4 (ECN) standard. The support of Ethernet Consist Network allows interconnection between end devices located in single consist of train and interoperability with IEC61375-2-5 (TBN).


Editable configuration file; USB port for import/export configuration
The configuration file of the switch can be imported and edited with word processor for the following switches to configure with ease. The USB port can import/export the configuration from/to USB dongle and also to upgrade firmware from USB dongle. TFTP/HTTP firmware upgrade is supported.


Event log & message; 2DI + 2DO; Factory default pin
The switch provides 2DI and 2DO. When disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the outside alarm and switch will send alert information to IP network with email and traps. The factory reset pin can restore the setting back to factory default.


Optional smart bypass protection on dual 10G copper ports
The bypass relay is set to bypass the switch to the next one when power is off to prevent network disruption. Lantech bypass caters to remain in bypass mode until the switch is completely booting up when power is back to avoid another network lost. Optional smart bypass (one pair) can be activated when switch encounters power failure. (-BT model)


Dual WVI input with max PoE budget and Inrush current protection
The switch accept 16.8~137.5VDC (WVI model) dual input with Ethernet and PoE galvanic isolation and PoE model can feed 54V output for PoE feeding with 160W budget. The inrush current on initial power up can be limited lower than 10 x nominal current.


EN50155, EN45545-2; EN61373 compliance; Rugged design with high ESD protection
The switch is designed to meet with critical network environment with IP41 aluminum enclosure and M12 connectors for water proof. The switch passed serious tests under extensive Industrial EMI and Safety standards. With EN45545-2 Fire & Smoke and EN50155 verification, it is best switch for railway on-board/track side, vehicle, and mining applications. For more usage flexibilities, the switch supports wide operating temperature from -40°C to 70°C (85°C operation for 10min), which is compliant with the EN50155 Operating Temperature Range Requirement Class OT4.


*Future release
**Optional

SPECIFICATIONS

Hardware Specifications

Standards

IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX
IEEE802.3ab 1000Base-T
IEEE802.3an 10Gbase-T
IEEE802.3x Flow Control and Back Pressure
IEEE802.3ad Port trunk with LACP
IEEE802.1d Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1s Multiple Spanning Tree
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
IEEE 802.1X User Authentication (Radius)
IEEE802.1p Class of Service
IEEE802.1Q VLAN Tag
IEEE802.3at/af Power over Ethernet

Switch Architecture

Back-plane (Switching Fabric): 128Gbps

Transfer Rate

14,880pps for Ethernet port
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Ethernet port

Mac Address

16K MAC address table

Jumbo frame

10KB

Connectors

10/100/1000T: 24 ports M12 8-pole X-coded with Auto MDI/MDI-X function
1G/2.5G/5G/10G Copper: 2 x ports M12 8-pole X-coded with Auto MDI/MDI-X function
1G/10G FX: 2x ports Q-ODC OM3 with multi-mode/single-mode Fiber
Power Input connector: 1 x M12 4-pole Male S-coded
Reset/Console/USB: 1 x M12 8-pole Female A-coded
DIDO: 1 x M12 5-pole Female A-coded

Network Cable

10Base-T: 4-pair STP Cat3 cable
100Base-TX: 4-pair STP Cat3/5 cable
1000Base-T: 4-pair STP Cat5/5e cable;
2.5G Copper: 4-pair STP Cat5e cable
10G Copper: 4-pair STP Cat6/6A cable

1G/10G fiber:
Multi-mode: 0 to 300 m, 850 nm (OM3 50/125 μm); Single-mode: 0 to 2 km, 1310 nm (9/125 μm)

LED

Per unit: Power 1 (Green), Power 2 (Green), FAULT (Red)
10/100/1000T Ethernet port: Link/Activity (Green), Speed (Green);
R.M. indicator (Green)
PoE: Link/Act (Green) (PoE model)
1G/2.5G/5G/10G Copper port: Speed (1G/2.5G/5G: Yellow; 10G: Orange)

DI/DO

2 Digital Input (DI):
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
2 Digital Output (DO): Open collector to 80 VDC, 50mA

Operating Humidity

5% ~ 95% (Non-condensing)

Operating Temperature

-40°C~70°C / -40°F~158°F (85°C operation for 10min.)

Storage Temperature

-40°C~85°C / -40°F~185°F

Power Supply

16.8~137.5VDC

PoE Budget (PoE model)

160W
Higher PoE budget can be applied upon request. **

PoE pin assignment (PoE model)

M12 port #1~#8 (-8 model); port #1~#8 & #17~#24 (-16 model); support IEEE 802.3at/af End-point, Alternative A mode

Power Consumption

Max. 54.3W exclude PoE load

Dimensions

IP41 Aluminum alloy case (rack mount):
440mm(W)x88mm(H)x357.2mm(D)

Weight

5 kgs

Installation

2U Rack mount design

EMI & EMS

FCC,
EN 55032:2015,
EN 55024:2010,
EN IEC 61000-6-2,
EN IEC 61000-6-4,
IEC 61000-4-2 (ESD),
IEC 61000-4-3 (RS),
IEC 61000-4-4 (EFT),
IEC 61000-4-5 (Surge),
IEC 61000-4-6 (CS),
IEC 61000-4-8 (Magnetic field)
BS EN61000-4-2,
BS EN61000-4-3,
BS EN61000-4-4,
BS EN61000-4-5,
BS EN61000-4-6,
BS EN61000-4-8,
BS EN55032, BS EN55024

Stability Testing

EN61373 (Shock and Vibration)

MTBF

TBC (standards: IEC 62380)

Verifications & report

EN50155:2017,
EN50121-3-2:2016,
EN50121-4:2016,
EN45545-1, EN 45545-2 Fire & Smoke verification

Warranty

5 years

Bypass**

One pair copper bypass module on 10G copper ports to pass to next switch in case of power failure.

Software Specifications

Lantech OS3 Platform

Learn more about Lantech OS3 Platform

*Future release
**Optional

DIMENSION

ORDERING INFORMATION

All model packages include M12 caps. All standard models are non-coating, optional coating models are available with –C model name. Optional bypass models are available with –BT model names.

P/N Model name Description
8361-010 TPGS-L6424XFTR-8-QMM-41-WVI 24 10/100/1000T w/8 PoE at/af up to 30W + 2 1G/10G Copper M12 X-coded + 2 10G Multimode Fiber Q-ODC OM3 300M EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ PoE galvanic isolation
8361-0101 TPGS-L6424XFTR-8-QMM-41-WVI-BT 24 10/100/1000T w/8 PoE at/af up to 30W + 2 1G/10G Copper M12 X-coded + 2 10G Multimode Fiber Q-ODC OM3 300M EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ PoE galvanic isolation; one pair Copper bypass
8361-0102 TPGS-L6424XFTR-8-QSM-41-WVI 24 10/100/1000T w/8 PoE at/af up to 30W + 2 1G/10G Copper M12 X-coded + 2 10G Single mode Fiber Q-ODC 2KM EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ PoE galvanic isolation
8361-0103 TPGS-L6424XFTR-8-QSM-41-WVI-BT 24 10/100/1000T w/8 PoE at/af up to 30W + 2 1G/10G Copper M12 X-coded + 2 10G Single mode Fiber Q-ODC 2KM EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ PoE galvanic isolation; one pair Copper bypass
8361-0104 TPGS-L6424XFTR-16-QMM-41-WVI 24 10/100/1000T w/16 PoE at/af up to 30W + 2 1G/10G Copper M12 X-coded + 2 10G Multimode Fiber Q-ODC OM3 300M EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ PoE galvanic isolation
8361-0105 TPGS-L6424XFTR-16-QMM-41-WVI-BT 24 10/100/1000T w/16 PoE at/af up to 30W + 2 1G/10G Copper M12 X-coded + 2 10G Multimode Fiber Q-ODC OM3 300M EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ PoE galvanic isolation; one pair Copper bypass
8361-0106 TPGS-L6424XFTR-16-QSM-41-WVI 24 10/100/1000T w/16 PoE at/af up to 30W + 2 1G/10G Copper M12 X-coded + 2 10G Single mode Fiber Q-ODC 2KM EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ PoE galvanic isolation
8361-0107 TPGS-L6424XFTR-16-QSM-41-WVI-BT 24 10/100/1000T w/16 PoE at/af up to 30W + 2 1G/10G Copper M12 X-coded + 2 10G Single mode Fiber Q-ODC 2KM EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ PoE galvanic isolation; one pair Copper bypass
8361-0108 TGS-L6424XFTR-QMM-41-WVI 24 10/100/1000T + 2 1G/10G Copper M12 X-coded + 2 10G Multimode Fiber Q-ODC OM3 300M EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ galvanic isolation
8361-01081 TGS-L6424XFTR-QMM-41-WVI-BT 24 10/100/1000T + 2 1G/10G Copper M12 X-coded + 2 10G Multimode Fiber Q-ODC OM3 300M EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ galvanic isolation; one pair Copper bypass
8361-0109 TGS-L6424XFTR-QSM-41-WVI 24 10/100/1000T + 2 1G/10G Copper M12 X-coded + 2 10G Single mode Fiber Q-ODC 2KM EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ galvanic isolation
8361-01091 TGS-L6424XFTR-QSM-41-WVI-BT 24 10/100/1000T + 2 1G/10G Copper M12 X-coded + 2 10G Single mode Fiber Q-ODC 2KM EN50155 OS3 Managed Ethernet Switch; 16.8V~137.5V dual input ; IP41 Rack mount design ; -40°C to 70°C ; w/ galvanic isolation; one pair Copper bypass


OPTIONAL ACCESSORIES - Software package

Please refer to Lantech OS3/OS4 platform


OPTIONAL ACCESSORIES - Connector

Model name Description
ECONM12-08A(M)-180 8 pin M12 (Male) A-coded 180 degree crimp type connector for reset/console/USB
ECONM12-05A(M)-C-180 5 pin M12 (Male) A-coded 180 degree crimp type connector for DI/DO
ECONM12-08X(M)-SPEEDCON 8 pin M12 (Male) X-coded 180 degree crimp type connector for data, Ethernet CAT6A (10G), shielded, SPEEDCON


OPTIONAL ACCESSORIES - Cable

Model name Description
ECONM12-SCODE(F)70CM CABLE 4 pin M12 (Female) S-coded cable for power supply, 70cm
ECONM12-08M2-CONSOLE 8 pin M12 (Male) A-coded 180 degree to RS232 cable for console, 150cm
ECABM12X83MSTP 8 pin M12 (Male) X-coded 180 degree RJ45 STP cable for data, shielded, 300cm
ECABMO02-QOP2-3.0-MM-OM3 Q-ODC 2 plug/LC multi-mode fiber, MM-OM3, 300cm
ECABMO02-QOP2-3.0-SM-OS2 Q-ODC 2 plug/LC single-mode fiber, SM-OS2, 300cm


OPTIONAL ACCESSORIES - Others

Model name Description
M12 to USB interface adapter 8 pin M12 (Male) A-coded 180 degree M12 to USB 2.0 interface adapter, 8cm
USB 2.0 Ethernet Adapter USB 2.0 to RJ45 Ethernet Adapter
ECONM12-08(M) TO DB9+USB2.0-1.5M CABLE 8 pin M12 (Male) A-coded 180 degree M12 to USB2.0 to DB9 (Female) cable, 150cm