240Watts, Dual Output Power with DIN Rail

  • Output voltage: 24V, 48V, 55V
  • Standard Operating Temperature: -20°C ~ 50°C
  • Built-in Fan cooled


WEEE


Datasheet

OVERVIEW

Lantech AD1240S Power series is rigid and compact design for space saving and industrial applications. It supports power ready signal and ring diode circuit for redundant application as well as over-voltage, over-load and short circuit protection. Attentive design to be snapped on DIN rail or wall mounted by bracket fits most of installation requirement. All models are RoHS compliant and meet with UL 60947 requirement.


FEATURES

  • High power density
  • Built-in fan cooled
  • RoHS compliance
  • 1-year warranty
  • Great reliability
  • DIN rail / Wall bracket mounting solution
  • Overvoltage protection
  • Overload protection
  • Short circuit protection
  • Optional alarm signal / Redundant function

SPECIFICATIONS

Hardware Specifications

Input Voltage

110/220AC±15% selectable

Input Frequency

47~63Hz

Input Inrush Current

22A/110VAC
44A/220VAC (Cold start)

Output Hold-up Time
(Fullload@220VAC)

20mS Min

Output Temp. Coefficient

±0.04% / °C

Output Overvoltage Protection

Auto recovery

Output Overload Protection

Power limited

Output Short Circuit Protection

Auto recovery

Transient response (Load change 50% to 100%)

Voltage deviation: 5%
Recovery time: 2mS

EMC Standards

EN 55011 Class B
EN 55022 Class B
EN 61000-4-2 Level 3
EN 61000-4-3 Level 3
EN 61000-4-4 Level 3
EN 61000-4-5 Level 3
EN 61000-4-6 Level 3
EN 61000-4-8 Level 3
EN 61000-4-11 Level 3

Safety Standards

UL

Operating Temperature

-20°C ~ 50°C (-4°F ~ 122°F)
ambient, derating each output at 2.5% per degree from 50°C ~ 70°C

Operating Humidity

Non-condensing, 5% ~ 95%RH

Vibration

Random vibration, 10Hz ~ 2KHz, 3axis

MTBF

120,000hrs Min. Per MIL-HDBK-217F, 25°C GB

Case Dimension

121(D)x110(H)x75(W)mm

Warranty

1 year

DIMENSION

ORDER INFORMATION

Model

O/P voltage Adjustment

Loading (A)

Ripple
Noise

Line Reg.

Load Reg.

Efficiency

Overvoltage
Protection

Min.

Rated

Max.

AD1240-24S

+24VDC±10%

0A

10A

10A

150mVp-p

±1%

±1%

83%

27~30VDC

AD1240-48S

+48VDC±10%

0A

5A

5A

250mVp-p

±1%

±1%

84%

52~56VDC

AD1240-48S-5

+55VDC±10%

0A

4.3A

4.3A

250mVp-p

±1%

±1%

84%

60~65VDC

Note:

  1. Each output can supply up to maximum current, but total loading cannot exceed rated output wattage.
  2. Line regulation is measured from low line to high line at rated load.
  3. Load regulation is measured from 20% to 100% of rated load at 110VAC input.
  4. Ripple & Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic capacitor parallel on the test point, at rated load and 110VAC input.
  5. Efficiency is measured at rated load and 110VAC input.