Products

Industrial EN50155 Switches

Industrial IEC 61850-3 Switches

Industrial DNV Type Switches

Industrial Managed Switches

IES-2008A
IES-2206F-II
IES-2208C
IES-2208F
IES-2216C
IES-2307C
IES-2307CI
IES-2307CFR
IGS-2206C
IGS-2404-E
LES-2400-RPS
LGS-2816C-RPS
LGS-2624C

Industrial PoE Series

Industrial Smart-Ring Switches

Industrial Entry Switches

Industrial Converters Series

Universal Redundant Fiber Controller

Industrial Wireless Access Point

Industrial / Serial Devices

Central Managed Switches

Smart Switches

PoE Series

Fiber Converters

SFP / Mini-GBIC

Software & Accessories

Software Product

Product Literature
 
 
     
   

White Papers

 
 

Case Study

 
 
IES-2307CI
 
 

7 10/100TX + 3 10/100/1000T with 100/1000M SFP Combo Industrial Managed Switch with DIDO and Internal Power Supply

 
  • Support Advanced SNMP including QoS,IPV6, IGMP Snooping and query, SSH/SSL
  • Supports DIDO (Digital input / output) function
  • Pro-Ring II : Pro-Ring II 10ms, Advanced Dual Homing, Daisy Couple Ring and Dual Ring Topology
  • Wide operating temperature range from -40°C to 75°C

  • Overview
  • Features
  • Specifications
  • Ordering Info
  • Dimensions
  • Downloads

OVERVIEW

The Lantech IES-2307CI is a 7-Port 10/100Base-TX + 3 10/100/1000T with 100/1000 SFP Combo Industrial Switch with SNMP functionality. The SNMP features are including QoS for 4 queues, 802.1q VLAN, IPV6, IGMP snooping and query, SSH/SSL, as well as SNTP and SMTP etc.

The Lantech IES-2307CI supports Pro-Ring (Legacy-Ring) and Pro-Ring II system. Pro-Ring(Legacy-Ring), an auto-recovery path within 10ms up to 250 Lantech Industrial Switches; Pro-Ring II is a new Ring mechanism for Lantech Industrial Switches in which it eliminates the need to pre-set the Master switch in previous Pro-Ring and yet to protect the network by much secure topologies than ever. It works as a Ring Chain to reduce the risk of master switch linking down whereas the setup becomes much easier. Pro-Ring II can be backward compatible with old Pro-Ring by down-grading the Ring scheme to old one.

The IES-2307CI DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IES-2307CI will immediately send an email to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors into the auto alarm system and transfer the alarm information to IP network with email and SNMP.

The IES-2307CI is designed to meet with critical network environment with IP 30 enclosure and test under extensive Industrial EMI and Safety standards. With wide temperature from -40°C~75°C, It is suitable for surveillance, factory automation, transportation, telecom / ISP outside terminal, heavy industrial factory and other factory assembly lines.


 

FEATURES

2DI (Digital input) & 2DO (Digital output) function

Pro-Ring II

  • Legacy-Ring.( Pro-Ring)
  • Pro-Ring II, Dual-Homing, Supports Daisy-Couple Ring, Multi-Couple Ring, Advanced Dual Homing, Key Ring, Multi-Key Ring, etc.
  • Provides Auto Master Selection, Single algorithm, Recovery time for Dual-Homing < 10ms, and 2 Redundant Ports

Wide Operating Temperature (-40°C ~75°C) for -E model

Port Trunk with LACP

Support IPv6

QoS, CoS supported

Security

  • Port Security: MAC address entries/filter
  • 10 IP address security management to prevent unauthorized intruder
  • Login Security: IEEE802.1X/RADIUS

IGMP Snooping & Query for Multi Media Applications

Supports Spanning Tree & RSTP

Support 802.1ab LLDP

Support SSH/SSL Security

Bandwidth Control

  • Ingress Packet Filter and Egress Rate Limit
  • Broadcast/Multicast Packet Filter Control

System Event Log

  • System Log Server/Client
  • SMTP e-mail Alert
  • Relay Alarm Output System Events

SNMP Trap

  • Device cold start, Power status, Authentication failure, Pro-Ring topology changed, Port Link up/Link down, DIDO open/close

3000VDC EFT & 6000VDC ESD protection

Optional Lantech-View Pro, Sever-client NMS

  • LANTECH-View Pro up to unlimited user

Hardware Specification

Standard

IEEE 802.3 10Base-T
IEEE 802.3u 100Base-TX
IEEE 802.3ab 1000Base-T
IEEE 802.3z Gigabit fiber
IEEE 802.3x Flow Control and Back-pressure
IEEE 802.3ad Port trunk with LACP
IEEE 802.1d Spanning Tree
IEEE 802.1w Rapid Spanning Tree
IEEE 802.1p Class of Service
IEEE 802.1Q VLAN Tag
IEEE 802.1x User Authentication (RADIUS)
IEEE 802.1ab LLDP

Switch Architecture

Back-plane (Switching Fabric): 7.4Gbps

Transfer Rate

14,880 pps for 10Base-T Ethernet port
148,800 pps for 100Base-TX/FX Fast Ethernet port
1,488,000 pps for Gigabit Fiber Ethernet port

Packet Buffer

1Mbits

Mac Address

8K MAC address table

Flash ROM

4Mbytes

DRAM

32Mbytes

Connector

10/100TX: 7 x RJ-45
10/100/1000T/ Mini-GBIC Combo: 3 x RJ-45 + 3 x
100/1000 SFP sockets
RS-232 connector: RJ-45 type

Network Cable

10Base-T: 2-pair UTP/STP Cat. 3, 4, 5, 6 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E, 6 cable
EIA/TIA-568 100-ohm (100m)
1000Base-T: 2-pair UTP/STP Cat. 5e or 6 cable
EIA/TIA-568 100-ohm (100m)

DI/DO

2 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
2 Digital Output(DO): Open collector to 40 VDC, 200mA

Optical Cable

Multi-mode: 50/125um~62.5/125um
Single mode: 9/125um
Available distance: 2km (Multi-mode)/30km (Single-mode)
Wavelength: 1310nm (Multi-mode/Single-mode)

LED

Power/ Power 1/ Power 2 (Green), Fault (Red), Ring Master Enable (Green), Ring Enable (Green)
Copper port : Link/Activity (Green), speed(Green/Orange) [Link/1000M]
SFP Fiber: Link/Activity (Green)

Protocol

CSMA/CD

Power Supply

AC 100~240V, 50/ 60Hz , 1A (Max. )
2* Redundant power: DC input: 24VDC (9~56VDC) with polarity reverse protects function and removable terminal block.

Reserve polarity protection

Present

Overload current protection

Present

Power Consumption

10.2Watts (internal power supply)

Operating Humidity

5% to 95% (Non-condensing)

Operating Temperature

-20°C~60°C / -4°F~140°F (Standard model)
-40°C~75°C / -40°F~167°F (-E model)

Storage Temperature

-40°C~85°C / -40°F~185°F

MTBF

260818 hrs

Case Dimension

IP-30, 217mm (W) x 141mm (D) x 66mm (H)

Weight

1300 g

Installation

DIN rail and rack mount ear.**

EMI & EMS

FCC Class A, CE EN61000-4-2 (ESD), CE EN61000-4-3 (RS), CE EN-61000-4-4 (EFT), CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS), CE EN61000-4-8, CE EN61000-4-11, CE EN61000-4-12, CE EN61000-6-2, CE EN61000-6-4

Safety

CE/EN60950-1

Stability Testing

IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration)

Warranty

5 years

Software Specification

Management

SNMP v1 v2c, v3/ Web/ Telnet/ CLI/ Lantech View Pro Management

SNMP MIB

RFC 1215 Trap, RFC1213 MIBII, RFC 1157 SNMP MIB, RFC 1493 Bridge MIB, RFC 2674 VLAN MIB, RFC 1643 , RFC 1757, RSTP MIB, Private MIB

VLAN

Port Based VLAN
IEEE 802.1Q Tag VLAN (256 entries) / VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.)
GVRP (256 Groups)

Port Trunk with LACP

LACP Port Trunk: 4 Trunk groups / Maximum 4 trunk members

LLDP

Supports LLDP to allow switch to advise its identification and capability on the LAN

Quality of Service

The quality of service determined by port, Tag and IPv4 Type of service, IPv4/IPv6 Different Service

Class of Service

Supports IEEE802.1p class of service, per port provides 4 priority queues

Spanning Tree

Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree

Pro-Ring

Legacy-Ring.Pro-Ring, Dual-Homing, Supports Daisy-Couple Ring, Multi-Couple Ring, Advanced Dual Homing, Key Ring, Multi-Key Ring.

Port Security

Supports 100 entries of MAC address for static MAC and another 100 for MAC filter

Port Mirror

Supports 3 mirroring types: “RX, TX and Both packet”.

IGMP

Supports IGMP snooping v1,v2
256 multicast groups and IGMP query
Supports multicast filter

IP Security

Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.
Support SSH/SSL

Login Security

IEEE802.1X Authentication/RADIUS

System Log

System log record and remote system log server

SMTP

SMTP Server and 6 e-mail accounts for receiving event alert

SNTP

SNTP to synchronize system clock in Internet

DHCP

DHCP Client/ DHCP Server/ IP Relay functions

Flow Control

Supports Flow Control for Full-duplex and Back Pressure for Half-duplex

DNS

Provides DNS client feature and support Primary and Secondary DNS server.

Relay Alarm

Provides one relay output for port breakdown, power fail and alarm.
Alarm Relay current carry ability: 1A @ DC24V

SNMP Trap

Up to 3 Trap stations
Cold start, Port link up, Port link down, Authentication Failure, Private Trap for power status, Port Alarm configuration, Fault alarm, Pro-Ring topology change, DIDO open/close contact

Bandwidth Control

Supports ingress packet filter and egress packet limit
The egress rate control supports all of packet type and the limit rates are 100K~250Mbps.

Ingress filter packet type combination rules are Broadcast/Multicast/Unknown Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all of packet. The packet filter rate can be set from 100k to 250Mbps.

Firmware Update

TFTP firmware update, TFTP backup and restore.

Configuration
upload and download

Supports binary configuration file for system quick installation

ifAlias

Each port allows importing 128bit of alphabetic string of word on SNMP and CLI interface.

*The Recovery Time of Pro-Ring: G-SFP<10ms ; G-T<150ms
**Optional


ORDERING INFOMATION

  • IES-2307CI……………….….......P/N: 8350-467
    7 10/100TX + 3 10/100/1000T With100/1000 SFP Comb
    Industrial Switch, Wide Operating Temperature (-20°C to 60°C)
    AC 100~240V


  • IES-2307CI-E……………….….......P/N: 8350-468
    7 10/100TX + 3 10/100/1000T With100/1000 SFP Comb
    Industrial Switch, Wide Operating Temperature (-40°C to 75°C)
    AC 100~240V

OPTIONAL ACCESSORIES

DIN Rail Power

  • AD1048-24FS
    24VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
    (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 18 Watts at 75°C.)
  • AD1024-24F
    24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
    (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 9 Watts at 75°C.)
  • AD1240-48S
    48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
    (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
  • AD1120-48F
    48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
    (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)


Mini GBIC

  • 8330-168    MINI GBIC 10/100/1000T (100m) Transceiver
  • 8330-162    MINI GBIC 1000SX (LC/0.5km) Transceiver
  • 8330-163    MINI GBIC 1000SX2 (LC/2km) Transceiver
  • 8330-165    MINI GBIC 1000LX (LC/10km) Transceiver
  • 8340-0591  MINI GBIC 1000LHX (LC/40km) Transceiver
  • 8330-166    MINI GBIC 1000XD (LC/50km) Transceiver
  • 8330-169    MINI GBIC 1000XD (LC/60km) Transceiver
  • 8330-167    MINI GBIC 1000ZX (LC/80km) Transceiver
  • 8330-170    MINI GBIC 1000EZX (120km) Transceiver
  • 8330-060    100Base FX 2KM, Multi-mode, LC Transceiver
  • 8330-065    100Base FX 5KM, Multi-mode, LC Transceiver
  • 8330-061    100Base LX 30KM, Single-mode, LC Transceiver
  • 8330-188    LTSFP-1000BX-10KM Transceiver (WDM 1310)
  • 8330-189    LTSFP-1000BX-10KM Transceiver (WDM 1550)
  • 8330-186    LTSFP-1000BX-20KM Transceiver (WDM 1310)
  • 8330-187    LTSFP-1000BX-20KM Transceiver (WDM 1550)
  • 8330-180    LTSFP-1000BX-40KM Transceiver (WDM 1310)
  • 8330-182    LTSFP-1000BX-40KM Transceiver (WDM 1550)
  • 8330-181    LTSFP-1000BX-60KM Transceiver (WDM 1310)
  • 8330-183    LTSFP-1000BX-60KM Transceiver (WDM 1550)
  • 8330-184    LTSFP-1000BX-80KM Transceiver (WDM 1490)
  • 8330-185    LTSFP-1000BX-80KM Transceiver (WDM 1550)


Rack Mounting Ear

  • MBAK003085   19” Rack Mounting Ear for 217x141x66mm Industrial Switch

DIMENSIONS (unit=mm)

DOWNLOADS

Description
Download

IES-2307CI Datasheet

IES-2307CI Manual

IES-2307CI Firmware

 


 

©2010, Lantech communications Global, Inc. All rights Reserved